One SF-C21 can do the work of four safety relay units. |
Small, so the unit can be installed in a narrow space Long-life semiconductor output (PNP) adopted for control output and auxiliary output |
Easy to monitor status with a generalpurpose PLC |
Note: Communication information can not be used for safety control. |
Simply turn a switch to set |
|
|
Refer to " 8 preset logics"
Easy to set the "OFF delay"
The OFF delay time can be easily set by simply turning the rotary switch to any one of patterns.
* The OFF delay time applies to control output 2. In case of setting the OFF delay time to control output 1, the "Configurator SF-C" software is needed.
Password protection prevents inadvertent logic changes
Easy to create a reliable safety circuit Use our "Configurator SF-C" software to build your own safety circuits of connected devices, control logic, output modes, etc. No programming skills required! |
Customized logics are safety-certified too!! |
Note:
Please make sure that the combination of logics and input devices complies with each machine safety standard.
Logic No.1:Overall stop control
When any connected input becomes OFF, the entire control output will be OFF. |
Logic No.2:Parallel muting control
When the muting input becomes ON, the light curtain will be temporarily disabled. |
Logic No.3:Sequential muting control
Only when the muting input becomes ON following a predefined sequence, the light curtain will be temporarily disabled. |
Logic No.4:Partial stop control 1
When the emergency stop input is OFF, the entire control output will be OFF. When any other input is OFF, its corresponding control output will be OFF. |
Logic No.5:Partial stop control 2
When the emergency stop input or the input from the back-end process becomes OFF, the entire control output will be OFF. When the input from the front-end process becomes OFF, only its corresponding control output will be OFF. |
Logic No.6:Two-hand control
This control is applied when a two-hand operation switch is used for control.Only when both switches of the two-hand operation switch are operated within 0.5 sec., control output will be ON. |
Logic No.7:OR control
Even when the guard (input A) is OFF, if the enabling switch is ON the control output will be ON. If either the emergency switch or input B becomes OFF, the entire control output will be OFF regardless of the status of the input A and emergency switch. |
Logic No.8:Operation mode selection control
Only when mode selection using the key selector is followed by the enabling switch being turned ON, the control output will be ON regardless of the open / close status of the guard. |
TITLE | DOCUMENT TYPE | SIZE |
SF-C21 | Catalog | 2491 KB |
---|---|---|
SF-C21 Overview of additional features | Catalog | 1680 KB |
SF-C21 | Manual | 5046 KB |
SF-C21 | Manual | 932 KB |