Compact Industrial SCARA
Compact Industrial Robot with light weight space saving arm. Its high speed operation is best suited for pick and place, labelling, tracking
last update: April 3, 2017
Power supply voltage |
Isolated power supply |
24 VAC/DC 100 to 240 VAC |
---|---|---|
Power consumption |
24 VAC/DC: 1.8 VA/1.0 W max. 100 to 240 VAC: 3.5 VA max. |
|
Rated input voltage | 3-phase, 200 to 480 VAC (3-wire) | |
Operating time |
Phase sequence on three- phase voltage input |
0.1 s±0.05 s |
Phase loss on three-phase voltage input |
0.1 s max. (when the voltage changes rapidly from 100% to 0% of rated voltage) |
|
PTC thermistor input | 0.2 s max. | |
Reset method |
Manual reset/automatic reset (switchable) Note: Manual reset method: Press the TEST/RESET button. |
|
Indicators |
Power (PWR): Green, PH_Alarm outputs (ALM): Red, TS_Alarm outputs (ALM): Red |
|
Output relays | One SPDT relay output (normally closed operation) | |
Output relay ratings |
Rated load Resistive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity: 1,250 VA, 150 W Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Electrical life: 5 A at 250 VAC or 30 VDC: 50,000 operations 3 A at 250 VAC or 30 VDC: 100,000 operations |
|
Ambient operating temperature | -20 to 60°C (with no condensation or icing) | |
Storage temperature | -25 to 65°C (with no condensation or icing) | |
Ambient operating humidity | 25% to 85% (with no condensation) | |
Storage humidity | 25% to 85% (with no condensation) | |
Altitude | 2,000 m max. | |
Terminal screw tightening torque | 0.49 to 0.59 Nm | |
Terminal wiring method |
Recommended wire Solid wire: 2.5 mm2 Twisted wires: AWG16, AWG18 Note: 1. Ferrules with insulating sleeves must be used with twisted wires. 2. Two wires can be twisted together. Recommended ferrules Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact Al 1-8RD (for AWG18) manufactured by Phoenix Contact Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact |
|
Case color | N1.5 | |
Case material | PC and ABS, UL 94 V-0 | |
Weight | Approx. 150 g | |
Mounting | Mounts to DIN Track. | |
Dimensions | 22.5 × 90 × 100 mm (W × H × D) |
Allowable operating voltage range | 85% to 110% of rated power supply voltage | |
---|---|---|
Allowable operating frequency range | 50/60 Hz ±5 Hz | |
Input frequency | 50/60 Hz | |
Input overload capacity | Continuous 528 V | |
Phase loss detection level |
80%±10% of rated input If any phase-to-phase voltage drops to 80%±10% of the other phase-to- phase voltages, voltage asymmetry is detected and the phase loss function is performed. |
|
PTC thermistor |
Operating value precision | 3,100 Ω ±5% |
Reset value precision | 1,650 Ω ±5% | |
Short circuit detection value precision |
0 to 10 Ω ±5 Ω | |
Temperature drift | ±0.1%/°C max. | |
Operating time repeatability | ±50 ms | |
Applicable standards |
Conforming standards |
EN 60947-5-1 Installation environment (pollution level 2, installation category III) |
EMC | EN 60947-5-1 | |
Safety standards |
UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA: C22.2 No.14, CCC: GB14048.5 |
|
Insulation resistance |
20 MΩ min. Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and output terminals Between input terminals and output terminals |
|
Dielectric strength |
2,000 VAC for one minute Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and output terminals Between input terminals and output terminals |
|
Noise immunity |
1,500 V power supply terminal common/normal mode Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time |
|
Vibration resistance |
Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions |
|
Shock resistance | 100 m/s2, 3 times each in 6 directions along 3 axes | |
Degree of protection | Terminals: IP20 |
last update: April 3, 2017
K8AK-TS1
K8AK-PT1
TITLE | DOCUMENT TYPE | SIZE |
K8AK-TS/PT | Catalog | 1188 KB |
---|---|---|
K8AK-TS1/PT1 Thermistor motor protection relay instruction sheet (Precautions for Safe Use) |
Manual | 66 KB |