Omron, S8NR-S/S8R-BB Series
Switch Mode Power Supply
S8NR-S / S8R-BB
Brand:
IP67 compliance and integrated functionality simplify the construction of power and safety circuits outside of control panels.

[Design] Solves in-panel space and heat issues. Functional integration reduces the engineering effort required for designing and selecting external circuits

In addition to an IP67 power supply with built-in electronic circuit protectors, the DC Blocking box enables power and safety circuits to be constructed outside the control panel with reduced effort.

Contributes to space saving and simplified thermal design inside control panels

DX1 Features 1

Contributes to reducing the effort required for off panel circuit design and component selection

DX1 Features 2

[Startup] Reduces the workload of on-site workers through more efficient installation and wiring

Intuitive installation and wiring reduce installation time, easing the burden on on-site operators and improving layout flexibility.

Easy installation using keyhole mounting, similar to hanging a wall clock

DX1 Features 3

DIN rail mounting simplifies installation and replacement work

In addition to screw mounting, DIN rail mounting is also supported. Simply snap the unit onto the rail for quick installation. Position adjustments can be easily made by sliding the unit left or right on the DIN rail, allowing flexible response to equipment modifications or specification changes.

DX1 Features 4

DIN rail mounting bracket : order seperately

Tool-free connector connection significantly reduces wiring time

DX1 Features 5

Build Safety Circuits Outside the Control Panel with Reduced Wiring

Safety circuits can be easily installed outside the control panel using an IP67-rated DC Blocking Box with a built-in Forcible Guided Relay. With the reduced-wiring configuration(using a 8ーpin model), the DC Blocking Box and the Safety I/O Block can be connected using a single signal cable, significantly reducing wiring work and installation time.

DX1 Features 6

[Startup] Smooth and Efficient Startup with Clear Status Visualization

With the built-in digital display, measured and setting values can be easily monitored, reducing adjustment errors and allowing fast commissioning.

Work efficiency is also improved during testing and recovery operations.

The high-visibility digital display allows anyone to easily and accurately check operating status and configure settings, improving work efficiency.

No tester is required―values can be confirmed using the display only.

The IP67 power supply adopts a connector-based connection method designed with a focus on water and dust resistance as well as ease of wiring, and features a highly visible digital display that allows users to check voltage and current status at a glance without using a tester.

NJ Features 7

Precise Configuration of Each Circuit Helps Prevent Startup Issues

By setting the cutoff current to match the wire gauge, thinner wires can be used. Fine control of the startup sequence further helps prevent on-site issues.

Each channel is equipped with an electronic circuit protector (CP), and the cut-off current can be set in 0.1 A increments.

NJ Features 8

The startup sequence for each channel can be set in 0.1-second increments.

NJ Features 9

[Maintenance] Minimize Downtime through Predictive Maintenance and Easy Fault Identification

By visualizing the power supply status, preventive maintenance and identification of abnormal points become easier, enabling fast and efficient maintenance.

Clear Status Indication with LEDs and Monitor

The power supply status can be checked at a glance using LEDs and the monitor, helping to reduce maintenance work.

Advance Maintenance with Replacement Timing Notification

By visualizing the remaining service life, preventive maintenance becomes possible, reducing downtime caused by sudden line stoppages.

NJ Features 10

Remaining Current Display for Easy Expansion Decisions

The remaining current of each channel is displayed, allowing immediate judgment on whether additional devices can be connected and helping to shorten evaluation time.

NJ Features 11

Easy Identification of Faulty Channels with Electronic CP per Channel

Each channel is equipped with an electronic circuit protector (CP). The operating status of each channel can be easily checked via channel-specific LEDs, reducing maintenance effort. In addition, the operating status of each channel can also be monitored via IO-Link communication.

NJ Features 12

Improved Maintenance Efficiency with Remote Parameter Monitoring and Configuration

IO-Link communication enables remote monitoring and configuration of various parameters, as well as channel-by-channel ON/OFF control. This improves on-site work efficiency after startup.

NJ Features 13

Key Lock Function Prevents Misoperation

The key lock function helps prevent problems caused by accidental changes to display screens or settings. In addition, IO-Link communication allows disabling setting changes and channel ON/OFF key operations on the power supply unit itself. In monitor mode, only display switching and key lock operations are enabled.

NJ Features 14

Recently Viewed
FOCUSED PRODUCT
Compact Industrial SCARA
Compact Industrial Robot with light weight space saving arm. Its high speed operation is best suited for pick and place, labelling, tracking
Thyristor Power Unit
3 phase Thyristor Power unit with current rating capacity of 30A/40A/60A/80A/100A/120A/160A/200A/250A/300A & 400Amps
NEW ARRIVALS
High Speed Counter Unit
High- speed counter unit ideal for edge control, achieving high- speed response and high-resolution performance.
Related Products