NA5-[]W and NA5-[]U have the same specifications and performance characteristics of hardware and software.
NA5-[]W and NA5-[]U have the same specifications and performance characteristics of hardware and software.
Item | Specification | ||||
---|---|---|---|---|---|
NA5-15W | NA5-12W | NA5-9W | NA5-7W | ||
Display panel *1 |
Display device | TFT LCD | |||
Screen size | 15.4 inches | 12.1 inches | 9.0 inches | 7.0 inches | |
Resolution | 1,280 × 800 dots (horizontal ✕ vertical) | 800 × 480 dots (horizontal ✕ vertical) | |||
Colors | 16,770,000 colors (24 bit full colors) | ||||
Effective display area |
331 × 207 mm (horizontal ✕ vertical) |
261 × 163 mm (horizontal ✕ vertical) |
197 × 118 mm (horizontal ✕ vertical) |
152 × 91 mm (horizontal ✕ vertical) |
|
View angles | Left: 60°, Right: 60°, Top: 60°, Bottom: 60° | ||||
Backlight *2 | Life | 50,000 hours min. *3 | |||
Brightness adjustment |
200 levels | ||||
Front panel indicators *4 |
RUN | Light green: Normal operation Light red: Error |
Model | Standard range |
---|---|
NA5-15W[][][][] NA5-12W[][][][] NA5-9W[][][][] NA5-7W[][][][] |
Number of light and dark pixels: 10 or less. (There must not be 3 consecutive light/dark pixels.) |
Item | Specification | |||
---|---|---|---|---|
NA5-15W | NA5-12W | NA5-9W | NA5-7W | |
Touch panel | Method: Analog resistive membrane type | |||
Resolution: 16,384 ✕ 16,384 | ||||
Life: 1,000,000 operations | ||||
Function keys * | 3 inputs (capacitance inputs) |
Item | Specification | |||
---|---|---|---|---|
NA5-15W | NA5-12W | NA5-9W | NA5-7W | |
User data capacity | 256 MB |
Item | Specifications (Same for all models.) | |
---|---|---|
Ethernet ports |
Applications |
Port 1: Connecting to anything other than the Sysmac Studio, e.g., device connections and VNC clients Port 2: Connecting to the Sysmac Studio in addition to the applications of port 1. |
Number of ports | 2 ports | |
Compliant standards |
IEEE 802.3i (10BASE-T), IEEE 802.3u (100BASE-TX), and IEEE 802.3ab (1000Base-T) |
|
Transmission media | Shielded twisted-pair (STP) cable: Category 5, 5e, or higher | |
Transmission distance | 100 m | |
Connector | RJ-45 8P8C modular connector | |
USB host ports |
Applications | USB Memory Device, keyboard, or mouse |
Number of ports | 2 ports | |
Compliant standards | USB 2.0 | |
Transmission distance | 5 m max. | |
Connector | Type-A connector | |
USB slave port |
Applications | Sysmac Studio connection |
Number of ports | 1 port | |
Compliant standards | USB 2.0 | |
Transmission distance | 5 m max. | |
Connector | Type-B connector | |
Serial port * |
Applications | Device Connection |
Number of ports | 1 port | |
Compliant standards | RS-232C | |
Transmission distance | 15 m max. | |
Connector | D-DUB 9-pin female connector | |
SD Memory Card slot |
Applications | To transfer or store the project or to store log data. |
Number of slots | 1 slot | |
Compliant standards | SD/SDHC | |
Expansion Unit connector * |
Applications | Expansion Unit |
Quantity | 1 |
* The serial port and Expansion Unit connector are for future expansion.
Item | Specification | |||
---|---|---|---|---|
NA5-15W | NA5-12W | NA5-9W | NA5-7W | |
Rated supply voltage | 24 VDC | |||
Allowable power supply voltage range |
19.2 to 28.8 VDC (24 VDC ±20%) | |||
Allowable momentary power interruption time |
Operation for momentary power interruption is not specified. | |||
Power consumption | 47 W max. | 45 W max. | 40 W max. | 35 W max. |
Ambient operating temperature |
0 to 50°C *1 *2 | |||
Ambient storage temperature |
-20 to +60°C *3 | |||
Ambient operating humidity |
10 to 90% *2 Must be no condensation. |
|||
Atmosphere | Must be free from corrosive gases. | |||
Pollution degree | 2 or less: JIS B 3502, IEC 61131-2 | |||
Noise immunity | 2 kV on power supply line (Conforms to IEC 61000-4-4.) | |||
Vibration resistance (during operation) |
Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5 mm half amplitude and 8.4 to 150 Hz with 9.8 m/s2 for 100 minutes each in X, Y, and Z directions (Time coefficient of 10 minutes ✕ coefficient factor of 10 = total time of 100 min.) |
|||
Shock resistance (during operation) |
Conforms to IEC 60028-2-27. 147 m/s2 3 times each in X, Y, and Z directions |
|||
Dimensions |
420 ✕ 291 ✕ 69 mm (W ✕ H ✕ D) |
340 ✕ 244 ✕ 69 mm (W ✕ H ✕ D) |
290 ✕ 190 ✕ 69 mm (W ✕ H ✕ D) |
236 ✕ 165 ✕ 69 mm (W ✕ H ✕ D) |
Panel cutout dimensions |
392 +1,0 ✕ 268 +1,0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 |
310 +1,0 ✕ 221 +1,0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 |
261 +1,0 ✕ 166 +1,0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 |
197 +0.5,0 ✕ 141 +0.5,0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 |
Weight | 3.2 kg max. | 2.3 kg max. | 1.7 kg max. | 1.3 kg max. |
Degree of protection |
Front-panel controls: IP65 oil-proof type, UL Type 4X (at initial state) To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of the rubber packing. |
|||
Battery life |
Battery life: 5 years at 25°C The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up by a super capacitor for 5 minutes after removing the old battery. (This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.) |
|||
International standards *5 |
UL 508/CSA standard C22.2 No.142 *6 EMC Directive (2004/108/EC) EN 61131-2: 2007 Shipbuilding standards LR, DNV, and NK IP65 oil-proof, UL Type 4X *7 (front panel only) ANSI 12.12.01 Class 1 Division 2/CSA standard C22.2 No. 213-M1987 (R2013) RoHS Directive (2002/95/EC) KC Standards KN 61000-6-2: 2012-06 for EMS and KN 61000-6-4: 2012-06 for EMI RCM |
1. The ambient operating temperature is subject to the following restrictions, depending on the mounting angle.
• The ambient operating temperature is 0° to 40°C when the mounting angle is 0° or more and less than 45° to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 45° or more and 90° or less to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 90° or more and 135° or less to the horizontal.
2. Use the Programmable Terminal within the following temperature and humidity ranges.
3. Store the Programmable Terminal within the following temperature and humidity ranges.
4. When the NA-[]WATW01 High-pressure waterproof attachment is used, the panel thickness is between 1.6 to 4.5 mm.
5. Check with your OMRON representative or refer to the following OMRON website for the latest information on the applicable standards for each model: www.ia.omron.com.
6. Use power supply Class 2 to conform to UL Standards.
7. Use the NA-[]WATW01 High-pressure waterproof attachment (sold separately) to conform to UL Type 4X.
NA series and Programming Devices
NA series | Corresponding unit versions/version | ||
---|---|---|---|
Model | NA system version |
NJ/NX/NY-series Controller NX1P2-[][][][] NJ501-[][][][] NY512-[][][][] NJ301-[][][][] NY532-[][][][] NJ101-[][][][] NX701-[][][][] |
Sysmac studio |
NA5-15W NA5-12W NA5-9W NA5-7W |
1.07 or later | NX1P2: 1.13 or later | 1.17 or higher |
1.06 or later |
NY512: 1.12 or later NY532: 1.12 or later |
1.17 or higher | |
1.02 or later |
NX701: 1.10 or later NJ101: 1.10 or later |
1.13 or higher | |
1.01 or later |
NJ501: 1.01 or later NJ501 Database Connection: 1.05 or later NJ301: 1.01 or later |
1.11 or higher |
Manufacturer | Models | Connection method | Communications driver |
---|---|---|---|
OMRON |
NX1P2-[][][][] NJ501-[][][][] NY512-[][][][] NJ301-[][][][] NY532-[][][][] NJ101-[][][][] NX701-[][][][] |
Built-in EtherNet/IP port | Ethernet |
CJ2H-CPU64/65/66/67/68-EIP CJ2M-CPU31/32/33/34/35 |
Built-in EtherNet/IP port | CIP Ethernet | |
CJ2H-CPU64/65/66/67/68-EIP CJ2M-CPU31/32/33/34/35 |
CJ1W-EIP21 | ||
CJ2H-CPU64/65/66/67/68-EIP CJ2M-CPU31/32/33/34/35 |
Built-in EtherNet/IP port | FINS Ethernet | |
CJ1H-CPU65H/66H/67H CJ1H-CPU65H/66H/67H-R CJ1G-CPU42H/43H/44H/45H CJ1M-CPU11/12/13/21/22/23 CJ2H-CPU64/65/66/67/68(-EIP) CJ2M-CPU11/12/13/14/15 CJ2M-CPU31/32/33/34/35 |
CJ1W-ETN21 CJ1W-EIP21 |