Connect with just one cable via built-in Ethernet
Connect with just one cable via built-in Ethernet
Embedded Ethernet I/F realizes just one connection to the system without any network converter. Wiring work can be reduced.
3 types of industrial Ethernet protocols enable to connect any type of PLC with easy programming.
Multiple Reader/Writers can be easily connected by using a Switching HUB. System design and system expansion can be configured easily.
Note : Contact your OMRON sales representative for the Connection Procedure Manual.
Communication Diagnostic via LED status indicators
On-site operators can easily check the communications status with the indicators of the Reader/Writer.
The indicators using easy-to-see high-brightness LED can be easily seen from a distance.
The Reader/Writer measures the communications signal and ambient noise levels to diagnose its stability,then indicates in LED and report to Host System.Easily and quickly checks the proper installation of the system, and helps to reduce startup time. This can be used for preventing errors during operation.
Note
1. Communication Diagnostic is disabled in the default settings.
2. The communication time is longer when enabling Communication Diagnostic.
For details, refer to the User's Manual (Cat. No. Z339 or Z353).
Can control multiple Reader/Writers by sending just one command.
The Reader/Writers installed on both sides of the conveyor can access the RF Tags
on the pallets even if the pallets are not placed with the same orientation.
Operate via web browser on your computer
Enable all parameter settings, execute RF Tag communications, and check the operation log anywhere by just connecting the computer.
Up to 2000 communication results are stored and guidance for the “Warning” results is provided.
Can be quickly recovered from trouble without expert knowledge.
Latest 2,048 communication results are logged and checked.
Diagnostic results can be shown by the graph.
Analysis time to identify the cause of unstable communication can be reduced by checking the time-series signal and noise levels.
The results can be output to CSV files.
Select from four languages: English, Chinese, Korean and Japanese.
Versatile selection, IPx9K support, and longer communication range
V680S RF Tag series offers 8 kinds of full combinations based on Communication Range, Mounting Materials, Memory Sizes.
Making it Easy to find the suitable RF Tag for your application.
RF Tag is molded by PPS resin which has superior oil and chemical resistance specification. It can be washed-down by a steam cleaner without removing from the pallet.
*1. IPx9K is a protection standard regarding high temperature and high-pressure water.
V680S series RF Tags are optimally designed to be used with V680S series Reader/Writers. Communication Range are up to 30% longer than those of existing models. This enables more flexible system design.
*2. When using some combinations of V680S series RF Tag and V680S series Reader/Writer.
last update: April 01, 2015
Model | V680S-HMD63-EIP
V680S-HMD63-PNT |
V680S-HMD64-EIP
V680S-HMD64-PNT |
V680S-HMD66-EIP
V680S-HMD66-PNT |
---|---|---|---|
Dimensions | 50W × 50H × 30D
(excluding protruding parts and cables) |
75W × 75H × 40D
(excluding protruding parts and cables) |
120W × 120H × 40D
(excluding protruding parts and cables) |
Power supply voltage | 24 VDC (-15% to +10%) | ||
Consumption current | 0.2A max. | ||
Ambient operating temperature | -10 to +55 °C (with no icing) | ||
Ambient operating humidity | 25% to 85% (with no condensation) | ||
Ambient storage temperature | -25 to 70 °C (with no icing) | ||
Ambient storage humidity | 25% to 85% (with no condensation) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) between cable terminals and case | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case | ||
Vibration resistance | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude,
acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in 6 directions (Total: 18 times) | ||
Degree of protection | IP67 (IEC 60529: 2001)
Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1) * |
||
Materials | Case: PBT resin, Filled resin: Urethane resin | ||
Mass | Approx. 240g | Approx. 390g | Approx. 760g |
Installation method | Reader/Writer: Two M4 screws
(Use a screw of 12 mm or more in length.) Branch cable joint: One M4 screws |
Four M4 screws
(Use a screw of 12 mm or more in length.) |
|
Host device communications
interface |
Ethernet 10BASE-T/100BASE-TX | ||
Host device communications
protocol |
EtherNet/IP, PROFINET | ||
Accessories | Instruction Sheet, Description of Regulations and Standard, IP address label |
* Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: The 0.5 m cable with two M12 connectors is attached to the Reader/Writer. The cable cannot be removed.
Model | V680S-HMD63-ETN | V680S-HMD64-ETN | V680S-HMD66-ETN |
---|---|---|---|
Dimensions | 50W × 50H × 30D
(excluding protruding parts) |
75W × 75H × 40D
(excluding protruding parts) |
120W × 120H × 40D
(excluding protruding parts) |
Power supply voltage | 24 VDC ( - 15% to + 10%) | ||
Consumption current | 0.2A max. | ||
Ambient operating temperature | - 10 to + 55 °C (with no icing) | ||
Ambient operating humidity | 25% to 85% (with no condensation) | ||
Ambient storage temperature | - 25 to 70 °C (with no icing) | ||
Ambient storage humidity | 25% to 85% (with no condensation) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) between cable terminals and case | ||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case | ||
Vibration resistance | No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude,
acceleration: 100 m/s2, 10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in 6 directions (Total: 18 times) | ||
Degree of protection | IP67 (IEC 60529: 2001)
Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1) *1 |
||
Materials | Case: PBT resin, Filled resin: Urethane resin | ||
Mass | Approx. 120g | Approx. 270g | Approx. 640g |
Installation method | Two M4 screws
(Use a screw of 12 mm or more in length.) |
Four M4 screws
(Use a screw of 12 mm or more in length.) |
|
Host device communications
interface |
Ethernet 10BASE-T/100BASE-TX | ||
Host device communications
protocol |
MODBUS TCP | ||
Accessories | Instruction sheet, Description of Regulations and Standard, IP address label, Ferrite core *2 |
*1 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
*2 Provided only with the V680S-HMD66-ETN.
Model | V680S-D2KF67 | V680S-D2KF67M | V680S-D2KF68 | V680S-D2KF68M |
---|---|---|---|---|
Memory capacity | 2,000 bytes (user area) | |||
Memory type | FRAM | |||
Data Retention | 10 years after writing (85 °C or less) | |||
Memory life | One trillion writes for each block (85 °C or less), Access frequency *1: One trillion accesses | |||
Ambient operating
temperature |
-20 to 85 °C (with no icing) | |||
Ambient storage
temperature |
-40 to 125 °C (with no icing) | |||
Ambient operating
humidity |
35% to 85% | |||
Degree of protection | IP68 (IEC 60529:2001),
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *2. IPX9K (DIN 40 050) |
|||
Vibration resistance | No abnormality after application of
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
No abnormality after application of
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps each in X, Y, and Z directions for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2,
3 times each in X, Y, and Z directions (Total: 18 times) |
|||
Dimensions | 40 × 40 × 5 mm (W × H × D) | 86 × 54 × 10 mm (W × H × D) | ||
Materials | PPS resin | |||
Weight | Approx. 11.5 g | Approx. 12 g | Approx. 44 g | Approx. 46 g |
Metal countermeasures | None | Provided | None | Provided |
*1 The number of accesses is the total number of reads and writes.
*2 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Model | V680S-D8KF67 | V680S-D8KF67M | V680S-D8KF68 | V680S-D8KF68M |
---|---|---|---|---|
Memory capacity | 8,192 bytes (user area) | |||
Memory type | FRAM | |||
Data Retention | 10 years after writing (85 °C or less) | |||
Memory life | One trillion writes for each block (85 °C or less), Access frequency *1: One trillion accesses | |||
Ambient operating
temperature |
-20 to 85 °C (with no icing) | |||
Ambient storage
temperature |
-40 to 125 °C (with no icing) | |||
Ambient operating
humidity |
35% to 85% | |||
Degree of protection | IP68 (IEC 60529:2001),
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *2. IPX9K (DIN 40 050) |
|||
Vibration resistance | No abnormality after application of
10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
No abnormality after application of
10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s2, 10 sweeps each in X, Y, and Z directions for 11 minutes each |
||
Shock resistance | No abnormality after application of 500 m/s2,
3 times each in X, Y, and Z directions (Total: 18 times) |
|||
Dimensions | 40 × 40 × 5 mm (W × H × D) | 86 × 54 × 10 mm (W × H × D) | ||
Materials | PPS resin | |||
Weight | Approx. 11.5 g | Approx. 12 g | Approx. 44 g | Approx. 46 g |
Metal countermeasures | None | Provided | None | Provided |
*1 The number of accesses is the total number of reads and writes.
*2 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User’s Manual (Cat. No. Z339).
Model | V680-D1KP54T | V680-D1KP66T | V680-D1KP66MT | V680-D1KP66T-SP |
---|---|---|---|---|
Memory capacity | 1,000 bytes (user area) | |||
Memory type | EEPROM | |||
Data retention time | 10 years after writing (85 °C or less),
0.5 year after writing (85 °C to 125 °C) Total data retention at high temperatures exceeding 125 °C is 10 hours *1 |
10 years after writing
(85 °C or less) |
||
Write endurance | 100,000 writes for each block (25 °C) | |||
Ambient operating
temperature (during transmission) |
- 25 to 85 °C (with no icing) | During RF Tag
communications: -25 to 70 °C (with no icing) Not during RF Tag communications: -40 to 110 °C (with no icing) |
||
Ambient storage
temperature (during data backup) |
- 40 to 125 °C (with no icing)
Heat resistance: 1,000 thermal cycles each of 30 minutes at - 10 °C/150 °C, High temperature storage: 1,000 hours at 150 °C *2 200 thermal cycles each of 30 minutes at - 10 °C/180 °C, High temperature storage: 200 hours at 180 °C *3 |
- 40 to 110 °C
(with no icing) |
||
Ambient operating
humidity |
35 to 95% | |||
Degree of protection | IP67 (IEC 60529:2001)
Oil resistance equivalent to IP67G (JIS C 0920: 2003, Appendix 1) *4 |
IP68 (IEC 60529:2001)
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *4 |
IP67 | |
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude,
acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
|||
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in X, Y, and Z directions (Total:
18 times) |
|||
Appearance | 20 dia. × 2.7 mm | 34 × 34 × 3.5 mm | 95 × 36.5 × 6.5 mm
(excluding protruding parts) |
|
Materials | PPS resin | Exterior: PFA fluororesin
RF Tag filling: PPS resin |
||
Weight | Approx. 2 g | Approx. 6 g | Approx. 7.5 g | Approx. 20 g |
Metal
countermeasures |
None | None | Provided | None |
*1 After storing data at high temperatures, rewrite the data even if changes are not required. High temperatures are those exceeding 125 °C up to 180 °C.
*2 150 °C heat resistance: The heat resistance has been checked at 150 °C for up to 1,000 hours, and thermal shock has been checked through testing 1,000 thermal cycles each of 30 minutes at −10/150 °C. (Test samples: 22, defects: 0)
*3 180 °C heat resistance: The heat resistance has been checked at 180 °C for up to 200 hours, and thermal shock has been checked through testing 200 thermal cycles each of 30 minutes at −10 °C/180 °C. (Test samples: 22, defects: 0)
*4 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User's Manual (Cat. No. Z339).
Model | V680-D1KP58HTN |
---|---|
Memory capacity | 1,000 bytes (user area) |
Memory type | EEPROM |
Data Retention | 10 years after writing (85 °C or less), 0.5 year after writing (85 °C to 125 °C)
Total data retention at high temperatures exceeding 125 °C is 10 hours *1 |
Write Endurance | 100,000 writes for each block (25 °C) |
Ambient operating temperature
(during transmission) |
- 25 to 85 °C (with no icing) |
Ambient storage temperature
(during data backup) |
-40 to 250 °C (with no icing) *2
(Data retention: -40 to 125 °C) 1. 2,000 cycles of 30 minutes each between room temperature and 200 °C 2. 500 hours at 250 °C |
Ambient storage humidity | No restrictions. |
Degree of protection | IP67 (IEC 60529:2001)
Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1) *3 |
Vibration resistance | No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude,
acceleration: 150 m/s2, 10 sweeps each in X, Y, and Z directions for 15 minutes each |
Shock resistance | No abnormality after application of 500 m/s2, 3 times each in X, Y, and Z directions
(Total: 18 times) |
Materials | PPS resin |
Weight | Approx. 70 g |
*1 After storing data at high temperatures, rewrite the data even if changes are not required. High temperatures are those exceeding 125 °C up to 250 °C.
*2 Storing RF Tags under high temperatures or under heat cycles will adversely affect the performance of the internal parts and the service life of the RF Tags. The RF Tag were placed in the following high temperatures and then evaluated in-house. It was confirmed that no problems occurred.
1. 2,000 cycles of 30 minutes each between room temperature and 200 °C.
2. 500 hours at 250 °C.
*3 Oil resistance has been tested using a specific oil as defined in the OMRON test method.
Note: For details, refer to the User's Manual (Cat. No. Z339, Z353 or Z354).
last update: April 01, 2015
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
V680S-HMD63-EIP
V680S-HMD63-PNT
V680S-HMD64-EIP
V680S-HMD64-PNT
V680S-HMD66-EIP
V680S-HMD66-PNT
V680S-HMD63-ETN
V680S-HMD64-ETN
V680S-HMD66-ETN
V680S-D2KF67/-D2KF67M
V680S-D8KF67/-D8KF67M
V680S-D2KF68/-D2KF68M
V680S-D8KF68/-D8KF68M
V680-D1KP54T
V680-D1KP66T/-D1KP66MT
V680-D1KP66T-SP
V680-D1KP58HTN
V680-D1KP66T Attachment
V600-A86
V680-D1KP54T Attachment
V700-A80
V680S-A41 []M/V680S-A51 []M *
Special connector --- RJ45
* V680S-A51 []M is Flexible cables. Cable color is black.
V680S-A42 []M
Special connector --- Loose wires
V680S-A40 []M/V680S-A50 []M *
Special connector --- Special connector
* V680S-A51 []M is Flexible cables. Cable color is black.
Cable with Plugs on Both Ends (M12 Straight/RJ45) Wiring
XS5W-T421-[]MC-K
Cable with Plugs on Both Ends (M12 Right-angle/RJ45)
XS5W-T422-[]MC-K
Note: For details, refer to the Industrial Ethernet Connectors Catalog (Cat.No.G019).
TITLE | DOCUMENT TYPE | SIZE |
V680S series | Catlog | 10823 KB |
---|---|---|
V680S-HMD63-EIP/HMD64-EIP/HMD66-EIP reader/writer (EtherNet/IP™) |
Manual | 39315 KB |
V680S-HMD63-ETN/HMD64-ETN/HMD66-ETN reader/writer (Modbus TCP) |
Manual | 37254 KB |
V680S-series rfid reader/writer NJ series EtherNet/IP™ connection guide | Manual | 2373 KB |
V680S-series rfid reader/writer CJ series EtherNet/IP™ connection guide | Manual | 2355 KB |
V680-D1KP58HTN RF tag instruction sheet (Precautions for Correct Use) |
Manual | 287 KB |
V680S-HMD6-EIP RFID system reader/writer |
Manual | 851 KB |
V680S-HMD6-ETN RFID system reader/writer |
Manual | 697 KB |