A unique ZNA2502 Twin-Fan construction enables both a slimmer body and a greater air volume. Downsizing is possible with a greater level of capacity than previous models.
last update: August 21, 2013
A unique ZNA2502 Twin-Fan construction enables both a slimmer body and a greater air volume. Downsizing is possible with a greater level of capacity than previous models.
The HEPA filter used with the ZN Series has the capacity to filter 99.99% of 0.3μm particles.
The smaller fan section and the unique ventilation construction design provides a more uniform laminar airflow. Uniform air is provided over a wide area.
The air volume can be set to 5 different levels,from 0.3 to 1.8 m3/min for the ZN-A2502 and 1.0 to 5.0 m3/min for the ZN-A4105. The air volume can be checked with the large indicators in the middle.
The LED indicators indicate operation errors (e.g.,stopped fans) and when HEPA filter replacement is required. Located on two corners of the Unit, the LED indicators are visible from many angles.
An I/O interface is built in. An AC adapter or 24-VDC input can be selected for the power supply.
An alarm signal is output if the self-diagnosis function indicates HEPA filter replacement or error operation.
HEPA filters can be replaced without tools thanks to the use of buckles. Onsite maintenance time is reduced because filters can be replaced in a one-step operation.
last update: August 21, 2013
last update: June 17, 2013
Model | ZN-A2502D | ZN-A4105D | ZN-A6112 | ZN-A6112P |
---|---|---|---|---|
Air outlet dimension | 225 × 205 mm | 360 × 360 mm | 578 × 568 mm | |
Main filter/
Removal rate |
HEPA filter/ 99.99% of particles 0.3- μm and larger | |||
Air volume (m3/min) | 0.3 to 1.8 m3/min
(typical) |
1.0 to 5.0 m3/min
(typical) |
4 to 12 m3/min (typical) | |
Power supply
voltage |
24 VDC ± 10%, Ripple (p-p): 10% max. | |||
Current
consumption |
Airflow level 5:
2.1 A max. (RMS value) (Peak: 3 A) |
Airflow level 5:
3.5 A max. (RMS value) (Peak: 5.5 A) |
Airflow level 5:
24 VDC: 4.3 A max. (RMS value) (Peak: 8 A) |
|
Airflow levels | 5 levels
Settable by button operation Settable by serial (RS-422 or RS-485 *1) communications |
5 levels
Settable by button operation Settable by serial (RS-422 or RS-485 *1) communications Settable by ON/OFF signal input (3 levels) *2 |
||
Running noise | Airflow level 3: 53 dB (typical) | Airflow level 3: 53 dB (typical) | ||
Fan motor | Compact DC brushless
centrifugal blower x 2 |
DC brushless turbo
fan x 1 |
DC brushless turbo fan x 1 | |
Indicators | Operating status: Green/Red
Air volume: Blue |
|||
Filter clogging
detection |
Yes | No | Yes | |
External output | Alarm output 1:
Alarm output 1 turns OFF when one of the following events occurs. (Normally alarm output 1 is ON.) (Check indicator to find out which event occurred.) Filter is clogged. Fan error Cleaning alarm for discharge needle (when ZN- J-series Ionizer (sold separately) is connected) Discharge error (when ZN-J-series Ionizer (sold separately) is connected) Alarm output 2: Enabled only when ZN-J-series Ionizer (sold separately) is connected. Alarm output 2 turns OFF to indicate that cleaning is necessary for ZN-J Series discharge needles. (Normally alarm output 2 is ON.) |
Fan operation alarm output
Alarm output OFF in below cases (ON during normal operation) Fan not rotating (Including when power is OFF or on standby) Trouble Clogged filter (ZN-A6112P only) |
||
30 VDC, 50 mA max.
Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA. |
||||
Applicable Ionizer
Unit (Optional) |
ZN-J25A | ZN-J41A | None | |
Ambient
temperature range |
Operating and storage: 0 to 40 °C (with no icing or condensation) | |||
Ambient humidity
range |
Operating and storage: 35% to 85% (with no condensation) | |||
Applicable
contamination degree |
Pollution degree 2 | |||
Material | Top: Antistatic plastic, bottom: SECC | Top: ABS resin, HEPA filter frame: aluminum | ||
Dimensions (mm) | 250 × 250 × 97.5
mm (W × D × H) |
410 × 410 × 129.5
mm (W × D × H) |
714.4 × 654.4 × 174.3 mm (W × D × H)
(Height from attachment surface: 117.3) |
|
Weight (Packaged) | Approx. 2 kg
(Approx. 3.3 kg) |
Approx. 5.2 kg
(Approx. 8.6 kg) |
Approx. 12.5 kg (Approx. 17 kg) | |
Accessories | Instruction Sheet, Sealing parts,
Mounting screws, I/O connector (XW4B-06B1-H1) |
Instruction Sheet, Sealing parts,
Mounting screws, I/O connector (XW4B-10B1-H1) |
*1. Use the dip switches on the unit surface (connector surface) to switch between RS-422 and RS-485.
*2. Contact input: 5 mA max. ON current. Use input device of 30 V or higher withstand voltage.
Model | ZN-J25A | ZN-J41A |
---|---|---|
Applicable Air Clean Units | ZN-A2502D | ZN-4105D |
Power supply voltage | 24 VDC ± 10%, Ripple (p-p): 10% max. | |
Current consumption | 300 mA max | |
Discharge voltage | ± 7 kV max | |
Discharge method | Variable DC discharge | |
Static electricity removal
time (typical) *1 |
5 s max. | |
Ion balance (typical) *2 | ± 30 V max. | |
Indicators | Power (green), Cleaning notice (orange flashing), Cleaning alarm (orange), High voltage
error (red) |
|
External output | High voltage error, cleaning outputs: Output from photo MOS relay (30V DC, 300 mA
max.) |
|
Functions | Manual adjustment of ion balance, cleaning required detection, high voltage detection | |
Ambient temperature range | Operating and storage: 0 to 40 °C (with no icing or condensation) | |
Ambient humidity range | Operating and storage: 35% to 65% (with no condensation) | |
Materials | Unit: ABS, Discharge needles: Tungsten | |
Dimensions (mm) | 248 × 310 × 45 mm (W × D × H) | 408 × 470 × 45 mm (W × D × H) |
Weight (Packaged) | Approx. 0.6 kg (Approx. 1.4 kg) | Approx. 1.5 kg (Approx. 2.7 kg) |