Time range setting | 0.1 s | 1 s | 10 s | 1 min | 10 min | 1 h | 10 h | 100 h |
---|---|---|---|---|---|---|---|---|
Set time range | 0.1 to 1.2 s | 1 to 12 s | 10 to 120 s | 1 to 12 min |
10 to 120 min |
1 to 12 h | 10 to 120 h |
100 to 1,200 h |
Scale numbers | 12 |
last update: January 10, 2014
Time range setting | 0.1 s | 1 s | 10 s | 1 min | 10 min | 1 h | 10 h | 100 h |
---|---|---|---|---|---|---|---|---|
Set time range | 0.1 to 1.2 s | 1 to 12 s | 10 to 120 s | 1 to 12 min |
10 to 120 min |
1 to 12 h | 10 to 120 h |
100 to 1,200 h |
Scale numbers | 12 |
Power supply voltage *1 |
24 to 240 VAC/DC, 50/60 Hz *2 12 VDC *2 |
|
---|---|---|
Allowable voltage fluctuation range |
24 to 240 VAC/DC: 85% to 110% of rated voltage 12 VDC: 90% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.1 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption *4 | H3DKZ-A1 | At 240 VAC: 6.6 VA max. |
H3DKZ-A2 | At 240 VAC: 4.5 VA max. | |
Control output |
Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
*1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this
inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as
a sensor.
*2. DC ripple: 20% max.
*3. Actual value
*4. The power consumption is for mode A after the Timer times out.
*5. Refer to DC Power Consumptions (Reference Information) on Data sheet for DC power consumptions.
Accuracy of operating time | ±1% of FS max. | |
---|---|---|
Setting error | ±5% of FS * | |
Influence of voltage | ±2% of FS max. * | |
Influence of temperature | ±5% of FS max. * | |
Dielectric strength |
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts of different polarity: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Static immunity | Malfunction: 4 kV, Destruction: 8 kV | |
Vibration resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life expectancy |
Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |
EMC |
(EMI) EN61812-1 Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
|
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 120 g |
* Actual value.
Time range setting | 0.1 s | 1 s | 10 s | 1 min | 10 min | 1 h | 10 h | 100 h |
---|---|---|---|---|---|---|---|---|
Set time range | 0.1 to 1.2 s | 1 to 12 s | 10 to 120 s | 1 to 12 min |
10 to 120 min |
1 to 12 h | 10 to 120 h |
100 to 1,200 h |
Scale numbers | 12 |
Power supply voltage *1 |
24 to 240 VAC/DC, 50/60 Hz *2 12 VDC *2 |
|
---|---|---|
Allowable voltage fluctuation range |
24 to 240 VAC/DC: 85% to 110% of rated voltage 12 VDC: 90% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.1 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption | H3DKZ-F | At 240 VAC: 4.5VA max. *4 |
H3DKZ-FA | At 12 VDC: 0.6 W max. | |
Control output |
Contact output (SPDT): 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 24 VDC with resistive load *3, *4 |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
*1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this
inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as
*2. DC ripple: 20% max.
*3. Actual value.
*4. Refer to DC Power Consumptions (Reference Information) on Data Sheet for DC power consumptions.
Accuracy of operating time | ±1% of FS max. | |
---|---|---|
Setting error | ±5% of FS ±0.05 s max. * | |
Influence of voltage | ±2% of FS max. * | |
Influence of temperature | ±5% of FS max. * | |
Dielectric strength |
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Vibration resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life expectancy |
Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |
EMC |
(EMI) EN61812-1 Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
|
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 110 g |
* Actual value.
Time range setting | t1x1 | t1x10 |
---|---|---|
Star set time (t1) range | 1 to 12 s | 10 to 120 s |
Star-Delta transfer time (t2) | Select from 0.05, 0.1, 0.25, or 0.5 s. |
---|
H3DKZ-G | H3DKZ-GE | |
---|---|---|
Power supply voltage *1 | 24 to 240 VAC/DC, 50/60 Hz *2 | 240 to 440 VAC (50/60 Hz) |
Allowable voltage fluctuation range |
24 to 240 VAC/DC: 85% to 110% of rated voltage 240 to 440 VAC: 80% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.5 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption | At 240 VAC: 6.6 VA max. *4 | At 440 VAC: 34 VA max. |
Control output |
Contact output (Time-limit output: relay, Star output: SPDT, Delta output: SPDT): 5 A at 250 VAC with resistive load (cosφ = 1) 5 A at 24 VDC with resistive load *4, *5 |
I th 2 A AC-15 120 VAC: 1.5 A AC-15 240 VAC: 1 A AC-15 440 VAC: 0.3 A |
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
*1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this
inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as
a sensor.
*2. DC ripple: 20% max.
*3. Actual value.
*4. Refer to DC Power Consumptions (Reference Information) on Data Sheet for DC power consumptions.
*5. 125 VDC: 0.15 A max. with resistive load, 125 VDC: 0.1 A with L/R of 7 ms.
Minimum load: 10 mA at 5 VDC (P level, reference value)
H3DKZ-G | H3DKZ-GE | ||
---|---|---|---|
Accuracy of operating time | ±1% of FS max. | ||
Setting error | ±5% of FS ±0.05 s max. *1 | ||
Transfer time | Total error ± (25% of transfer time + 5 ms) max. *1 | ||
Influence of voltage | ±2% of FS max. *1 | ||
Influence of temperature | ±5% of FS max. *1 | ||
Dielectric strength |
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. *2 Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. *2 Between contacts of different polarity: 2,000 VAC 50/60 Hz for 1 min. *2 Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
||
Vibration resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions | |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | ||
Shock resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions | |
Malfunction | 100 m/s2 3 times each in 6 directions | ||
Life expectancy |
Mechanical |
10 million operations min. (under no load at 1,800 operations/h) |
10 million operations min. (under no load at 1,800 operations/h) |
Electrical |
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) |
100,000 operations min. (0.3 A at 440 VAC, resistive load at 1,800 operations/h) |
|
EMC |
(EMI) EN61812-1 Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
||
Degree of protection | IP30 (Terminal block: IP20) | ||
Weight | Approx. 120 g |
*1. Actual value.
*2. The dielectric strength of the H3DKZ-GE (240 to 440 VAC) is 2,500 VAC 50/60 Hz.
L Series | ||
---|---|---|
Time range setting | x1 | x10 |
Set time range | 1 to 12 s | 10 to 120 s |
Power ON time | 0.3 s min. | |
Scale numbers | 12 |
Supply voltage |
100 to 120 VAC, 50/60 Hz 200 to 240 VAC, 50/60 Hz |
|
---|---|---|
Allowable voltage fluctuation range | 85% to 110% of rated voltage | |
Power consumption | H3DKZ-HCL | At 120 VAC: 11.7 VA max. |
H3DKZ-HDL | At 240 VAC: 29.5 VA max. | |
Control output |
Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
* The control output ratings are for one H3DKZ operating alone.
Accuracy of operating time | ±1% of FS max. | |
---|---|---|
Setting error | ±5% of FS * | |
Influence of voltage | ±2% of FS max. * | |
Influence of temperature | ±5% of FS max. (±2% ±10 ms max. at 1.2-s range) * | |
Dielectric strength |
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Vibration resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life expectancy |
Mechanical | 10 million operations min. (under no load at 1,200 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) | |
EMC |
(EMI) EN 61812-1 Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN 61000-3-3 (EMS) EN 61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
|
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 120 g |
* Actual value.
last update: January 10, 2014
last update: January 10, 2014
H3DKZ-A
H3DKZ-F
H3DKZ-G
H3DKZ-GE
H3DKZ-H
DIN Track
PFP-100N
PFP-50N
DIN Track
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Note 1: Order the above products in multiples of 10.
Note 2: The Tracks conform to DIN standards.
last update: January 10, 2014
TITLE | DOCUMENT TYPE | SIZE |
H3DKZ | Catalog | 1961 KB |
---|