Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet.You can change the display color by setting it, but you cannot switch it based on the judgement results.
Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet.You can change the display color by setting it, but you cannot switch it based on the judgement results.
last update: August 06, 2015
Power supply voltage | 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC | |
---|---|---|
Allowable power supply voltage range |
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC |
|
Power consumption *1 |
100 to 240 V: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) |
|
Current consumption | DeviceNet power supply: 50 mA max. (24 VDC) | |
Input | DC voltage | |
A/D conversion method | Delta-Sigma method | |
External power supply |
10 VDC ±5%, 100 mA (models with external power supply only) or 5 VDC, 100 mA (models with external power supply only) |
|
Event inputs *2 |
Timing input |
NPN open collector or no-voltage contact signal ON residual voltage: 3 V max. ON current at 0 Ω: 17 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 1.5 mA max. |
Startup compensation timer input |
NPN open collector or no-voltage contact signal ON residual voltage: 2 V max. ON current at 0 Ω: 4 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max. |
|
Hold input | ||
Reset input | ||
Forced-zero input | ||
Bank input | ||
Output ratings (depends on the model) |
Relay output |
250 VAC, 30 VDC, 5 A (resistive load) Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations |
Transistor output |
Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 μA max. |
|
Linear output |
Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS (1 V or less: ±0.15 V; no output for 0 V or less) |
|
Display method |
Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green) |
|
Main functions |
Scaling function, measurement operation selection, averaging, previous average value comparison, forcedzero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset |
|
Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |
Ambient operating humidity | 25% to 85% | |
Storage temperature | -25 to 65°C (with no icing or condensation) | |
Altitude | 2,000 m max. | |
Accessories |
Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC (01)) and crimp terminals (Hirose HR31-SC-121) *3 |
*1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned
ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC
Power Supply Unit is recommended.
*2. PNP input types are also available.
*3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals
provided are for Thin Cables.
Display range | -19,999 to 99,999 | |
---|---|---|
Sampling period | 20 ms (50 times/second) | |
Comparative output response time |
100 ms max. | |
Linear output response time | 150 ms max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 2,300 VAC for 1 min between external terminals and case | |
Noise immunity |
100 to 240 VAC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) 24 VAC/VDC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) |
|
Vibration resistance |
Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions |
|
Shock resistance | 150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions | |
Weight | Approx. 300 g (Base Unit only) | |
Degree of protection |
Front panel | Conforms to NEMA 4X for indoor use (equivalent to IP66) |
Rear case | IP20 | |
Terminals | IP00 + finger protection (VDE0106/100) | |
Memory protection |
EEPROM (non-volatile memory) Number of rewrites: 100,000 |
|
Applicable standards |
UL61010-1, CSA C22.2 No. 61010-1-04 EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II EN61326-1 |
|
EMC |
EMI: EN61326-1 Industrial electromagnetic environment Electromagnetic radiation interference: CISPR 11 Group 1, Class A Terminal interference voltage: CISPR 11 Group 1, Class A EMS: EN61326-1 Industrial electromagnetic environment Electrostatic Discharge Immunity: EN61000-4-2: 4 kV (contact), 8 kV (in air) Radiated Electromagnetic Field Immunity: EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Electrical Fast Transient/Burst Immunity: EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line) Surge Immunity: EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line) Conducted Disturbance Immunity: EN61000-4-6: 3 V (0.15 to 80 MHz) Power Frequency Magnetic Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous time Voltage Dips and Interruptions Immunity: EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage) |
last update: August 06, 2015
last update: October 15, 2012
* DeviceNet models: 97 mm
Terminal: M3, Terminal Cover: Accessory
Mounting Recommended Panel Thickness 1 to 8 mm.
Mount the product horizontally.
last update: October 15, 2012
TITLE | DOCUMENT TYPE | SIZE |
K3HB-V | Catalog | 1514 KB |
---|---|---|
K3HB
digital indicators communications user's manual |
Manual | 2331 KB |
K3HB-S/-X/-V/-H
digital indicators user's manual |
Manual | 3382 KB |
K3HB-V
weighing indicator instruction sheet |
Instruction Manual | 1883 KB |