※ BD-300/600 sensor head models are only supported with firmware version 5.0 or higher of the amplifier unit (BD-A1) and communication converter (BD-C).
The sensors can accurately detect various target material or color including black/white paper, stainless steel, rubber, PCB, etc.
Movement average, differential, and median filters allow for accurate and stable correction in measurement values in the event of sudden changes from mechanical noise or other variables.
Median filter
removes any sudden value changes.
Movement average filter
averages the measured values to reduce the overall changes to the measurement values.
Differential filter
transmits the differential value between current and previous measured values. Used to measure sudden changes in value.
Supports various calculation functions (OFF, ADD-AB, SUB-AB, AVG)
- OFF: independent measurement (calculation function not used)
- ADD-AB: Adds the measured values from sensor heads A/B (used to measure thickness)
- SUB-AB: Subtracts the measured values from sensor heads A/B (used to measure level difference/
disparity)
- AVG: averages the measured values from all connected sensor heads (used to measure evenness)
- Cannot use more than 2 calculation functions with interconnected sensor amplifier units
The BD-600 model is capable of measuring up to 1 m suitable for in harsh environment including high temperatures, and also features easy measurement of width and step of thick steel plates.
Laser displacement sensors feature a maximum resolution of 1 ㎛ (BD-030) for stable and
precise measurements.
The BD-300 model features resolution of 20 ㎛
Up to 8 sensor amplifier units can be interconnected. The channels for the amplifier units are automatically sorted when connected together. (Each sensor amplifier unit requires independent power supply)
Dedicated software ‘atDisplacement’ offers user-friendly interface with live data, life graphs and wave graphs for easy monitoring of various measurement values in real-time. Set values can be immediately checked during the setting.
Real-time monitoring of set value (SV).
Displays the status of amplifier unit and measured value to number. The data is automatically scaled for ease of use in future analysis.
Displays the graph color of amplifier unit per channel and present value (PV).
Displays received light waveform per unit in real time. Up to 8 sensor units can be monitored.
1 m, 2 m, 5 m, 10 m cables are available for application in diverse environments without breaking.