• 1 and 2 cable types
• Meets EN ISO 13849-1 (PLd/Safety Category 3) and EN ISO 13856-1
• Can be used with MC3 safety MAT controller or NX safety controller
• Complies with north american safety standards including ANSI/RIA 15.06
last update: April 19, 2017
• 1 and 2 cable types
• Meets EN ISO 13849-1 (PLd/Safety Category 3) and EN ISO 13856-1
• Can be used with MC3 safety MAT controller or NX safety controller
• Complies with north american safety standards including ANSI/RIA 15.06
last update: April 19, 2017
last update: April 19, 2017
Detection Method | Pressure sensitive |
---|---|
Mat Type | Normally open SPST |
Mat Electrical Rating | 20.4 V to 28.8 V |
Activation Force | 300 N min. to 80 mm dia. test piece |
Maximum Load | 2,000 N to 80 mm dia. test piece
1,862 kPa (270 lbs/in.2) (rolling load (stationary)) |
Response Time | 50 ms max. |
Mechanical Durability | 1 x 106operations min. |
Mat Exit Cable | Model No. ending ‘-1’: 1 exit cable, M8 4-pin cable, 4 conductors, 22 AWG, male
Model No. ending ‘-2’: 2 exit cables, M8 3-pin cable, 2 conductors, 22 AWG, 1 male and 1 female |
Ambient operating
temperature |
-10 to 55°C (14 to 131°F) (with no icing or condensation) |
Ambient storage temperature | -10 to 55°C (14 to 131°F) (with no icing or condensation) |
Ambient operating humidity | 0 to 95% RH |
Degree of protection | IP65 |
Material (Mat cover) | Polyurethane |
Weight | Approx. 25 kg/m2 |
Model | MC3 |
---|---|
Power voltage | 24 VDC |
Operating voltage range | -15% to +15% of rated supply voltage |
Power consumption * | 3 W max. |
Rated load | 6 A at 230 VAC/6 A at 24 VDC (resistive load)
5 A at 230 VAC (AC15)/2 A at 24 VDC (DC13) (inductive load) |
Maximum rated voltage | 250 VAC/24 VDC |
Rated carry current | 6 A |
Maximum switching capacity | 1,500 VA |
* Power consumption of loads is not included.
Model | MC3 | |
---|---|---|
Response time | 30 ms max. | |
Safety input | Mat can be connected in series (Connectable number: 12 max.)
The external impedance must be 8 Ω or less between M11 and M21 and between M12 and M22. |
|
Safety output | SPDT-NO | |
Auxiliary output | SPDT-NC | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric
strength |
Between different
poles of outputs |
1,800 VAC, 50/60 Hz for 1 sec. |
Between power
supply and output |
||
Vibration resistance | Malfunction: 10 to 55 Hz, 0.15 mm single amplitude | |
Mechanical shock resistance | Malfunction: 98 m/s2 | |
Durability | Mechanical | 10,000,000 cycles min. |
Electrical | 100,000 cycles min. (rated load, switching frequency: 360 cycles/hour) | |
Ambient operating temperature | 0 to 55°C (with no icing or condensation) | |
Ambient operating humidity | 0% to 90% RH | |
Degree of protection | IP20 | |
Terminal tightening torque | 0.5 N·m | |
Weight | Approx. 360 g |
Conforming to Standards | EN ISO13856-1:2013, EN ISO13849-1:2015, ANSI/UL 508, CSA C22.2 No. 14 |
---|---|
Performance level (PL)/ safety category * | PL d/safety category 3 (EN ISO 13849-1:2015) |
PFHd * | 4.8× 10-8 |
* Applicable to integrated systems of UMA Safety Mats and MC3 Safety Mat Controller.
last update: April 19, 2017
(Unit: mm)
The UM[][]A-[]-[]-1 mat comes with a short 4-conductor quick disconnect cables with M8 4-pin connector at a corner of the safety mat.
The UM[][]A-[]-[]-2 mat comes with two short 2-conductor quick disconnect cables with M8 3-pin connector at two corners of the safety mat.
*1. Refer to model number structure on data sheet for more information.
*2. "Step" portion of mat (inactive) is used to "seat/place/hold" trim.
*3. The mat has the following inactive (non-sensing) area:
- 10 mm (20 mm at corners) with a test piece of 80 mm diameter
- 15 mm (30 mm at corners) with a test piece of 11 mm diameter
Single connector cable (M8, 4-socket)
Single connector cable to connect a 1-cable UMA Safety Mat to a MC3 safety mat controller.
UMA-CBL-4PCF-M8-[]M
Male-Female extension cable (M8, 4-pin)
Extension cable to connect a 1-cable UMA safety mat to a UMA-CBL-4PCF-M8-[]M single connector cable.
UMA-CBL-4PMF-M8-[]M
Single connector cable (M8, 3-socket)
Single connector cable to connect a 2-cable UMA safety mat to a MC3 safety mat controller.
UMA-CBL-3PCF-M8-[]M
Male-Female Extension Cable (M8, 3-pin)
Extension cable to connect a 2-cable UMA safety mat to a UMA-CBL-3PCF-M8-[]M Single connector cable or connect multiple 2-cable UMA safety mats in series.
UMA-CBL-3PMF-M8-[]M
Male-Male extension cable (M8, 3-pin)
Used to connect the connector sockets of 2-cable UMA safety mats together.
UMA-CBL-3PMM-M8-0.15M
Female-Female Extension Cable (M8, 3-pin)
Used to connect the connector plugs of 2-cable UMA safety mats together.
UMA-CBL-3PFF-M8-0.15M
UMRT[]
UMJS[]
UMAL
UMOC
UMIC
TITLE | DOCUMENT TYPE | SIZE |
UMA Series | Catalog | 5496 KB |
---|---|---|
UMA
Safety Mat |
Manual | 8538 KB |
SCC-1224A
Safety Mat/Edge Controller |
Manual | 1642 KB |
UMA
Safety Mat(Safety Precautions) (ENG/JPN) |
Instruction Manual | 252 KB |
SCC-1224A
Safety Mat/Edge Controller |