Model | E3ZS-T81A | E3FS-10B4 2M | E3FS-10B4-M1-M | |
---|---|---|---|---|
Sensor type | Through-beam models | |||
Safety category | See Applicable standards. | |||
Standard sensing object |
Opaque object: 18 mm in diameter or greater |
Opaque object: 11 mm in diameter or greater | ||
Lens diameter | Diameter 6.7 mm/diameter 9 mm | |||
Sensing distance | 0.2 to 3 m | 0 to 10 m | ||
Response time (under stable light incident condition) |
1.0 ms (E3ZS only) | 2.0 ms (E3FS only) | ||
Startup waiting time | 100 ms | |||
Power supply voltage (Vs) |
12 to 24 VDC±10% (ripple p-p 10% max.) *1 |
24 VDC±10% (ripple p-p 10% max.) *1 | ||
Current consumption (no load) |
Emitter: 15 mA max. Receiver: 20 mA max. |
Emitter: 50 mA max. Receiver: 25 mA max. |
||
Light source (emitted wavelength) |
Red LED (660 nm) | Infrared LED (870 nm) | ||
Effective aperture angle (EAA) |
±5° (at 3 m) | |||
Control output (OSSD) |
PNP transistor output, load current: 100 mA max., Residual voltage: 1 V max., (when load current is less than 10 mA), Residual voltage: 2 V max. (when load current is between 10 mA and 100 mA) (except for voltage drop due to cable extension) *1 |
PNP transistor output, load current: 100 mA max., Residual voltage: 2 V max. (except for voltage drop due to cable extension) *1 |
||
Output operation mode | Light-ON *2 | |||
Input voltage |
22.5 to 24 VDC: Emitter OFF (source current: 3 mA max.) Open or 0 to 2.5 V: Emitter ON (leakage current: 0.1 mA max.) *1 |
21.5 to 24 VDC: Emitter OFF (source current: 3 mA max.) Open or 0 to 2.5 V: Emitter ON (leakage current: 0.1 mA max.) *1 |
||
Indicators |
Emitter: Emitting (orange); Receiver: Operation (orange), Stable (green) |
Emitter: Emitting (orange); Receiver: Output OFF (red), Output ON (green) |
||
Test functions | External test (light emission stop function by test input) | |||
Connection method | Pre-wired cable (2 m) | M12 connector | ||
Protective circuits |
Power supply/output reverse connection protection, load short- circuit protection |
Output reverse connection protection, load short-circuited protection |
||
Ambient temperature |
Operating: -10 to 55°C Storage: -10 to 70°C (with no icing or condensation) |
Operating: -20 to 55°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity | Operating: 35% to 85%, storage: 35% to 95% (with no icing or condensation) | |||
Ambient operating light intensity |
Incandescent lamp: 3000 lx max (light intensity on the receiver surface). Sunlight: 10,000 lx max (light intensity on the receiver surface). |
|||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1000 VAC 50/60 Hz 1 min | |||
Degree of protection | IP67 (IEC standard) | |||
Vibration resistance |
Operating limit | 10 to 55 Hz, double amplitude: 0.7 mm, 50 min each in the X, Y, and Z directions | ||
Malfunction | 10 to 55 Hz, double amplitude: 1.5 mm, 2 h each in the X, Y, and Z directions | |||
Shock resistance |
Operating limit | 100 m/s2, 1000 times in the X, Y, and Z directions | ||
Malfunction | 500 m/s2, 3 times each in the X, Y, and Z directions | |||
Material | Case: Polybutylene terephthalate | Case: ABS | Case: Brass | |
Weight (packed state) |
Approx. 120 g (for one set including 2-m cable) |
Approx. 150 g (for one set including 2-m cable) |
Approx. 125 g (for one set including only Sensor) |
|
Accessories | Operation manual |
Operation manual, nuts for mounting Emitter/Receiver (2 each) |
||
Applicable standards |
Sensor only |
IEC 60947-5-3 (PDDB) EN ISO13849-1 (PLc/Safety Category 1) |
--- | |
Sensor connected to G9SP |
IEC(EN)61496-1 Type2 ESPE *3 IEC (EN)61496-2 Type2 AOPD *4 EN ISO13849-1 (PLc/Safety Category 2) |
|||
Switching element category (from IEC60947-5-3) |
DC13 (control of electromagnetic load) | --- |