Use the DeviceNet Configurator for E5ZN initial settings and temperature control wiring to enable immediate execution.
Use the DeviceNet Configurator for E5ZN initial settings and temperature control wiring to enable immediate execution.
Measure the heater control time (RUN time monitor) to manage heater life expectancy.
Monitor supply voltages, such as those for Temperature Controller and Communications Unit power supplies, and network power supplies.
User-specified names can be set for each heater and Communications Unit, enabling the location of errors to be checked quickly.
Upload/download Temperature Controller parameters to the Communications Unit. This shortens the time required to replace Temperature Controllers.
Power supply voltage | DeviceNet | 24 VDC (for internal circuits) |
---|---|---|
External input power supply | 24 VDC (for RS-485 communications circuits and Temperature Controllers) | |
Allowable voltage range | DeviceNet | 11 to 25 VDC |
External input power supply | 20.4 to 26.4 VDC | |
Power consumption (See note 2.) |
DeviceNet | Approx. 1.1 W (for a current of 45 mA at 24 VDC) |
External input power supply | Approx. 0.5 W (for a current of 20 mA at 24 VDC) | |
Connectable Temperature Controllers | E5ZN Series | |
Maximum number of connectable Temperature Controllers | 16 | |
Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |
Ambient operating humidity | 25% to 85% | |
Ambient storage temperature | -25 to 65°C (with no icing or condensation) |
Insulation resistance | 20 MΩ min. (at 100 VDC) |
---|---|
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between the DIN track and all DeviceNet connector terminals and between the DIN track and all terminal socket terminals |
Vibration resistance | 10 to 55 Hz, 10 m/s2 for 2 hrs each in ±X, ±Y, and ±Z directions |
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions |
Weight | 100 g max. |
Safety standards |
cULus508 EMS: Electrostatic Discharge (ESD) EN61006-2, EN61000-4-2 (4 kV/contact, 8 kV/air) Radiated Electromagnetic Fields EN61006-2, EN61000-4-3 (10 V/m) Electrical Fast transients/BURST EN61006-2, EN61000-4-4 (2 kV/DC power-line, 1 kV/Signal-line) Surge Transients EN61006-2, EN61000-4-5 (line to ground : 1 kV/DC power-line) : 2 kV/Signal-line line to line : 0.5 kV/DC power-line) Conducted Disturbances EN61006-2, EN61000-4-6 (10 V) EMI: Radiated Emissions (electric field) EN50081-2 Class A |
Transmission line connection method |
RS-485 multipoint |
---|---|
Communications method | RS-485 (2-wire, half-duplex) |
Synchronization method |
Start-stop synchronization |
Baud rate | 38,400 bps |
Transmission code | ASCII |
Data bit length | 7 bits |
Stop bit length | 2 bits |
Error detection | Vertical parity (even) |
BCC (block check character) | |
Flow control | None |
Number of Units that can be connected in parallel |
16 Units max. (32 channels) |
TITLE | DOCUMENT TYPE | SIZE |
E5ZN-DRT | Catalog | 740 KB |
---|---|---|
E5ZN-DRT DeviceNet™ Communications Unit for E5ZN Temperature Controllers |
Manual | 2747 KB |
E5ZN-DRT DeviceNet Communications Unit for E5ZN Temperature Controller |
Manual | 851 KB |
E5ZN-SCT Terminal Unit |
Manual | 1179 KB |