Selector switch for secure equipment activation during maintenance
last update: February 18, 2015
Selector switch for secure equipment activation during maintenance
The guard lock of the operation unit prevents incorrect operation.
The key has the same shape as the following keys.
• The key of the A22TK safety key selector switch
• The trapped key of the D4JL guard lock safety-door switch
• The lockout key of the D4SL-NSK10-LK slide key unit
Because the A22LK guard lock safety key selector switch uses the same key as the guard lock safety-door switch, the operator is prevented from forgetting to remove the key. the result is a safer working environment when performing maintenance.
last update: September 01, 2015
Certification body | Standards | File No. |
---|---|---|
UL | UL508, CSA C22.2 No.14 | E76675 |
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
CQC(CCC) | GB140485 | 2014010305726263 |
KOSHA | KS C IEC 60947-5-1 | Consult your OMRON representative for details. |
Note: Only models with NC contacts have a direct opening mechanism.
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch.
Type | 24 VDC |
---|---|
Rated operating voltage (100% ED) | 24 VDC ±10% |
Current consumption | Approx. 88mA |
Insulation | Class A (130°C max.) |
Model | A22LK | |
---|---|---|
Allowable operating frequency |
Mechanical | 30 operations/minute max. |
Electrical | 30 operations/minute max. | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | Between terminals of same polarity | 2,500 VAC, 50/60Hz for 1min. |
Between each terminal and ground | 6,000 VAC, 50/60Hz for 1min. | |
Vibration resistance *1 | 10 to 55 Hz, 1.5mm double amplitude (within 1 ms) | |
Shock resistance | Destruction | 1000m/s2 |
Malfunction *1 | 300m/s2 | |
Durability | Mechanical | 100,000 operations min. |
Electrical | 100,000 operations min. | |
Ambient operating temperature *2 | -10 to +55°C | |
Ambient operating humidity | 35% to 85%RH | |
Degree of protection *3 | IP65 *3 | |
Electric shock protection class | Class II | |
Degree of contamination | 3 (EN60947-5-1) |
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm performance before application.
3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been used and contact reliability for smaller loads may be
reduced.
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
last update: September 01, 2015
last update: November 05, 2013
Note: Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions.
last update: November 05, 2013
TITLE | DOCUMENT TYPE | SIZE |
A22LK Series | Catalog | 1157 KB |
---|---|---|
A22LK Safety Key Selector Switch(ENG/JPN/KOR) |
Instruction Manual | 715 KB |