Because the A22TK safety key selector switch uses the same key as the guard lock safety-door switch, the operator is prevented from forgetting to remove the key. The result is a safer working environment when performing maintenance.
last update: January 06, 2014
Because the A22TK safety key selector switch uses the same key as the guard lock safety-door switch, the operator is prevented from forgetting to remove the key. The result is a safer working environment when performing maintenance.
*To unify keys, specify the same key type.
With the Selector Switch, it is possible to switch between normal operation mode (use of Door Switch is available) and maintenance mode (use of Enabling Grip Switch is available).
last update: January 06, 2014
last update: October 12, 2017
Certification body | Standards | File No. |
---|---|---|
UL *1 | UL508, C22.2 No.14 | E41515 |
TÜV SÜD |
EN60947-5-1 (certified direct opening mechanism) |
Consult your OMRON representative for details. |
CQC(CCC) | GB14048.5 | |
KOSHA | EN60947-5-1 |
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 has been obtained. (Certification has been obtained for the Switch Unit only)
Rated carry current (A) |
Rated voltage (V) |
Rated current (A) | |||
---|---|---|---|---|---|
AC15 (inductive load) |
AC12 (resistive load) |
DC13 (inductive load) |
DC12 (resistive load) |
||
10 | 24 VAC | 10 | 10 | --- | --- |
110 | 5 | 10 | |||
220 | 3 | 6 | |||
380 | 2 | 3 | |||
440 | 1 | 2 | |||
24 VDC | --- | --- | 1.5 | 10 | |
110 | 0.5 | 2 | |||
220 | 0.2 | 0.6 | |||
380 | 0.1 | 0.2 |
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by
conducting tests under thefollowing conditions.
(1) Ambient temperature: 20±2C°
(2) Ambient humidity: 65±5% RH
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
Model | A22TK | |
---|---|---|
Allowable operating frequency |
Mechanical | 30 operations/minute max. |
Electrical | 30 operations/minute max. | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | Between terminals of same polarity | 2,500 VAC, 50/60 Hz for 1 min. |
Between each terminal and ground | 2,500 VAC, 50/60 Hz for 1 min. | |
Vibration resistance *1 | 10 to 55 Hz, 1.5-mm double amplitude (within 1 ms) | |
Shock resistance | Destruction | 1000 m/s2 |
Malfunction *1 | 250 m/s2 max. | |
Durability | Mechanical | 100,000 operations min. |
Electrical | 100,000 operations min. | |
Ambient operating temperature *2 | 20 to +70°C | |
Ambient operating humidity | 35% to 85%RH | |
Ambient storage temperature | 40 to +70°C | |
Degree of protection | IP65 *3 | |
Electric shock protection class | Class II | |
PTI (tracking characteristic) | 175 | |
Degree of contamination | 3 (EN60947-5-1) |
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm performance before application.
3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been used and contact reliability for smaller loads may be
reduced.
last update: October 12, 2017
TITLE | DOCUMENT TYPE | SIZE |
A22TK | Catalog | 1271 KB |
---|---|---|
A22TK sefety key selector switch |