・Machinery Directive
・EN50041
・EN ISO 14119
・EN 60204-1
last update: September 17, 2015
・Machinery Directive
・EN50041
・EN ISO 14119
・EN 60204-1
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland |
EN60947-5-1 (certified direct opening) GS-ET-15 |
Consult your OMRON representative for details. |
UL | UL508 | E76675 |
CSA | CSA C22.2 No. 14 | LR45746 |
CQC (CCC) | GB14048.5 | 2003010305073833 |
Utilization category | AC-15 |
---|---|
Rated operating current (Ie) | 0.75 A |
Rated operating voltage (Ue) | 240 V |
Note: Use a 10 A fuse type a gI or gG that conforms to IEC60269 as a short-circuit protection device.
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC 480 VAC 600 VAC |
10 A |
60 30 15 12 |
6 3 1.5 1.2 |
7,200 | 720 |
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 1,000,000 operations min. |
Electrical | 500,000 operations min. (10 A resistive load at 250 VAC) | |
Operating speed | 0.1 m/s to 0.5 m/s | |
Operating frequency | 30 operations/minute max. | |
Direct opening force *3 | 19.61 N min. (EN60947-5-1) | |
Direct opening travel *3 | 20 mm min. (EN60947-5-1) | |
Contact resistance | 25 mΩ max. | |
Rated insulation voltage (Ui) | 600 V (EN60947-5-1) | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class I (with ground terminal) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity | 4 kV |
Between terminals of different polarity |
||
Between each terminal and ground | ||
Insulation resistance |
100 MΩ min. (at 500 VDC) between terminals of same or different polarity, between each terminal and ground, and between each terminal and non-current-carrying metal part |
|
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.65 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. (IEC68-2-27) |
Malfunction | 300 m/s2 min. (IEC68-2-27) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 20 A (EN60947-5-1) | |
Ambient operating temperature | -40 to 80°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 285 g (D4BS-15FS) |
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may
enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
*3. These figures are minimum requirements for safe operation.
last update: September 17, 2015
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. The insertion radii apply when the rotational center of the Operation Key in on surface A in the figures.
*2. The insertion radii apply when the rotational center of the Operation Key in on the Operation Key installation surface.
TITLE | DOCUMENT TYPE | SIZE |
D4BS | Catalog | 1798 KB |
---|---|---|
D4BS
safety door switch instruction sheet |
Catalog | 431 KB |