• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
last update: May 07, 2015
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD |
EN60947-5-1 (certified direct opening) |
Ask your OMRON representative for information on certified models. |
UL * | UL508, CSA C22.2 No.14 | E76675 |
CCC (CQC) | GB14048.5 | 2004010305105973 |
* Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 10 A | 60 | 6 | 7,200 | 720 |
240 VAC | 30 | 3 |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC | 2.5 A | 0.55 | 0.55 | 69 | 69 |
250 VDC | 0.27 | 0.27 |
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 1,000,000 operations min. |
Electrical |
500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) |
|
Operating speed | 2 to 360°/s | |
Operating frequency | 30 operations/minute max. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity |
2.5 kV |
Between terminals of different polarity |
4 kV | |
Between each terminal and non-current carrying metallic parts |
6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight |
Approx. 87 g (D4NH-1AAS) Approx. 97 g (D4NH-1ABC) |
Note: 1. The above values are initial values.
2. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been used and contact reliability for smaller loads may be
reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust or water penetration, do not use the D4NH in places where foreign material such as dust, dirt,
oil, water, or chemicals may enter through the head. Otherwise, accelerated wear, Switch damage, or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details,
consult your OMRON representative.
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is
possible with the actual load beforehand.
last update: May 07, 2015
TITLE | DOCUMENT TYPE | SIZE |
D4NH | Catalog | 1868 KB |
---|---|---|
D4NH safety-door hinge switch instruction sheet |
Manual | 485 KB |