・ Machinery Directive
・ EN ISO 14119
・ EN 60204-1
last update: October 07, 2015
・ Machinery Directive
・ EN ISO 14119
・ EN 60204-1
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland |
EN60947-5-1 (certified direct opening) GS-ET-19 |
Consult your OMRON representative for details. |
UL | UL508 | E76675 |
CSA | CSA C22.2, No.14 | LR45746 |
CQC (CCC) | GB14048.5 | 2003010305073836 |
Type | Standard model | Indicator model |
---|---|---|
Utilization category | AC-15 | AC-15 |
Rated operating current (Ie) | 3 A | 6 A |
Rated operating voltage (Ue) | 250 V | 115 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC |
10 A |
60 30 |
6 3 |
7,200 | 720 |
Note: The UL/CSA certified rating for products with indicators (-A) is 6 A/115 VAC.
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 1,000,000 operations min. |
Electrical | 500,000 operations min. (10 A resistive load at 250 VAC) | |
Operating speed | 0.05 to 0.5 m/s | |
Operating frequency | 30 operations/minute max. | |
Direct opening force *3 | 19.61 N min. (EN60947-5-1) | |
Direct opening travel *3 | 20 mm min. (EN60947-5-1) | |
Holding force | 700 N min. (GS-ET-19) | |
Contact resistance | 50 mΩ max. | |
Rated insulation voltage (Ui) | 300 V (EN60947-5-1) | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class I (with ground terminal) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity | 4 kV |
Between terminals of different polarity | ||
Between each terminal and ground | ||
Between solenoid and ground | 2.5 kV | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.35 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -10 to 55°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 800 g |
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals may
enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%.
*3. These figures are minimum requirements for safe operation.
Type | 24 VDC mechanical lock models | 24 VDC solenoid lock models |
---|---|---|
Rated operating voltage | 24 VDC (+10%, -15%) (100% ED) | |
Current consumption | Approx. 300 mA | |
Insulation class | Class B (130°C or less) |
Rated voltage | 10 to 115 VAC/VDC |
---|---|
Current leakage | Approx. 1 mA |
Color (LED) | Orange, green |
last update: October 07, 2015
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application.
TITLE | DOCUMENT TYPE | SIZE |
D4BL | Catalog | 1368 KB |
---|---|---|
D4BL guard lock safety-door switch instruction sheet |
Instruction Manual | 584 KB |